Please confirm topic selection

Are you sure you want to trigger topic in your Anconeus AI algorithm?

Please confirm action

You are done for today with this topic.

Would you like to start learning session with this topic items scheduled for future?

Review Question - QID 100853

In scope icon M 2 E
QID 100853 (Type "100853" in App Search)
A 55-year-old man with chronic dyspnea is intubated and started on mechanical ventilation for respiratory failure. Pressure-volume scalars on the ventilator show decreased change in volume for each unit change in pressure as compared to normal values. Of the following options, which is the most likely cause of his respiratory failure?

Amyotrophic lateral sclerosis

6%

9/159

Asthma

1%

2/159

Centriacinar emphysema

11%

18/159

Pulmonary fibrosis

75%

120/159

Alpha-1-antitrypsin deficiency

5%

8/159

Select Answer to see Preferred Response

bookmode logo Review TC In New Tab

A decreased change in volume for each unit change in pressure (decreased compliance, or decreased dV/dP) is the hallmark of pulmonary fibrosis.

Idiopathic pulmonary fibrosis is diagnosed if there is a pattern of usual interstitial pneumonia (honeycombing) on high-resolution CT. Biopsy results may confirm diagnosis if CT is not definitive. Connective tissue diseases, drug toxicity, exposure to asbestos and causes of hypersensitivity pneumonitis must be ruled out through history and laboratory testing. Pulmonary function testing reveals restricted volume, normal flow (or above normal), with evidence of decreased gas exchange.

Barreiro and Perillo provide an overview of spirometry interpretation. Provided patient effort is good, the first step is to determine whether the pattern is obstructive (FEV/FVC<0.7) or restrictive (FEV/FVC>0.7, FVC decreased). They provide an algorithm in Figure 3 for further interpretation of spirometry results.

Papandrinopoulou et al. review the effects of chronic obstructive pulmonary disease on lung compliance. They provide examples of low compliance states besides IPF, including infant respiratory distress syndrome, tuberculosis, asbestos exposure, or cardiovascular causes such as mitral stenosis and left ventriuclar failure. Higher than normal compliance may be due to emphysema, bronchodilator therapy, or pulmonary stenosis.

Illustration A compares flow-volume loops in restrictive (A) vs. normal (B) vs. obstructive (C) lung diseases.
Illustration B shows a gross pathology specimen of lungs with the changes indicative of pulmonary fibrosis.

Incorrect Answers:
Answer 1: ALS affects respiratory muscles, causing decreased total pressure, but not changes in lung compliance until late-stage disease when the chest wall stiffens.
Answer 2: Asthma causes small increases in pulmonary compliance.
Answer 3: Centriacinar emphysema causes lung parenchyma to have an increased lung compliance.
Answer 5: Alpha-1-antitrypsin deficiency is a cause of emphysema and increases lung compliance.

ILLUSTRATIONS:
REFERENCES (2)
Authors
Rating
Please Rate Question Quality

3.3

  • star icon star icon star icon
  • star icon star icon star icon
  • star icon star icon star icon
  • star icon star icon star icon
  • star icon star icon star icon

(3)

Attach Treatment Poll
Treatment poll is required to gain more useful feedback from members.
Please enter Question Text
Please enter at least 2 unique options
Please enter at least 2 unique options
Please enter at least 2 unique options